Comparison of Iodine-124 (I-124) and Iodine-131 (I-131) Radiopharmacokinetics in Patients Prepared With Recombinant Human TSH Injection (rhTSH)



Status:Terminated
Conditions:Cancer, Cancer, Endocrine, Thyroid Cancer
Therapuetic Areas:Endocrinology, Oncology
Healthy:No
Age Range:18 - Any
Updated:11/3/2018
Start Date:December 2008
End Date:October 2018

Use our guide to learn which trials are right for you!

Comparison of I-124 and I-131 Radiopharmacokinetics in Patients Who Have Well-differentiated Thyroid Cancer and Are Prepared With Recombinant Human TSH Injection (rhTSH)

This research study is to compare the radiopharmacokinetics of I-124 to the
radiopharmacokinetics of I-131 in patients who have well-differentiated thyroid cancer after
recombinant human thyroid-stimulating hormone (rhTSH) injection. I-131 is routinely used for
imaging and dosimetry for patients with well-differentiated thyroid cancer. In this study,
I-124 is administered orally in capsular form, and the radiopharmacokinetics of I-124 is
compared with I-131. I-124 is another isotope of iodine, which is cyclotron-produced. I-124
has multiple advantages:

- Ideal Half-Life (4.2 days) for delayed imaging.

- High resolution tomographic imaging.

- Feasibility of quantitating lesion uptake.

- Potential of dosimetry for the planning of radioiodine therapy.

Voluntary patients will have I-124 dosimetry performed in addition to the I-131 dosimetry,
which is planned as part of routine clinical care. I-124 dosimetry is composed of four parts:
(1) two extra doses of injections of rhTSH, (2) the administration of I-124, (3) PET imaging,
and (4) drawing blood samples.

Patients will receive two additional injections of rhTSH. This is similar to the procedure
for I-131 dosimetry. Second, they will receive I-124. I-124 is similar to I-131 except I-124
decays in a different way to emit a positron so that the PET scanner can be used for imaging.
I-124 is given in the form of one or several capsules, which are taken by mouth. This is also
similar to I-131. Third, PET/CT imaging is done for approximately 30 minutes to one hour on
five consecutive days. Radiation from PET/CT scan is far less than what they receive from a
diagnostic CT scan. For the fourth part, a technologist will draw about 5 cc from the forearm
on each of the five consecutive days. This is also similar to I-131.

Initially, all patients will be randomized to one of two study groups. The first group will
have the I-131 dosimetry performed first followed by the I-124 dosimetry, and the second
group will have the I-124 dosimetry performed first followed by the I-131 dosimetry.

The risk of this study is considered very low, and the potential benefits to the patient are
considered very high.

Radiopharmacokinetics and Dosimetric Calculations

A tracer dosage of either I-131 or I-124 is first administered to the patient, and the
clearance is then followed for the specified period. In the classical approach, the blood is
considered the critical organ which is irradiated either from the

- particles emitted from activity in the blood itself, or from the

- emissions originating from activity dispersed throughout the remainder of the body.
Therefore only two compartments need to be monitored for radioactivity: (a) blood and
(b) the whole body. Based on a classical dosimetry approach, the radiation dose to the
whole blood in cGy (rads) per MBq I-131 is calculated.

The calculation of the area under these two curves is based on a mathematical fit to the data
points using a multiple exponential function. Since the data collection is terminated after 4
days these curves must then be extrapolated to infinity. A very conservative estimate is
employed by assuming that the clearance following the final measured data point is based
simply on the physical decay. This ignores any biological clearance and results in an
overestimation of the area of these tails and hence in the radiation dose per millicurie
administered.

Each patient will have the following calculated.

i. Whole body radiopharmacokinetics

ii. Blood radiopharmacokinetics

iii. Whole blood dosimetry

iv. Lesion Kinetics

i. Whole body radiopharmacokinetics

As an alternative to using an external probe to measure the whole body retention, a dual
detector gamma camera system can be used. In this case the patient is scanned in the whole
body mode in a reproducible geometry while lying supine on the imaging table. This method has
been generally accepted for patient-specific whole body dosimetry of I-131 radiolabeled
antibodies . Furthermore, it has been shown to yield comparable results with the external
probe data . This technique has the following features:

- Simultaneous anterior and posterior images using a high-energy collimator.

- Table height, detector radii, scan length, scan speed, and energy window are
standardized and reproduced for each data point.

- Scan speed can be relatively rapid (typically we have used 30 cm/min) so that the data
acquisition is completed in approximately 8 minutes.

- Additional scans are performed each day for (1) background, and (2) a counting standard
(vial containing about 37 MBq (1 mCi) of I-131).

- Total counts in the image or fixed regions of interest encompassing the entire body are
used for the calculation of whole body retention.

Although the images are not used for diagnostic purposes, this approach has the additional
advantage that if for some reason there is delayed absorption of the tracer dosage in the
stomach, and then the measurement could be repeated at 4 hours.

During the initial 2-hour period following the I-131 administration the patient is not
allowed to urinate or defecate. Under these circumstances essentially 100 percent of the
dosage will be contained within the patient at these observation points. The initial image is
then defined to represent the 100 percent value and subsequent daily measurements are
normalized to this value using the formula:

When used in this way, the standard will correct for variations in detector sensitivity from
measurement to measurement, as well as for physical decay. Absolute calibrations are not
necessary since the patient is used as his/her reference.

The whole body I-124 images will be obtained at the same time points using the PET system. In
this case emission imaging will be obtained for 1-2 minutes/bed position for a sufficient
number of positions to cover the patient from head to foot. Transmission imaging will also be
performed to correct the emission data for attenuation.

ii. Blood pharmacokinetics

The blood samples (3-4 ml in purple top tubes) are counted using scintillation well-detector
system. Since we need to determine the activity in these samples, it is necessary to make up
a calibration standard, which can be counted at the same time. This involves the addition of
a carefully assayed quantity of I-131 (approximately 3.7 MBq - 7.4 MBq {100-200 uCi}) to a
total volume of 1000 ml. Such a small concentration is necessary in order to avoid saturating
the detector. An alternative that we have implemented in the dosimetry program here at the
Washington Hospital Center uses a Ba-133 rod source instead that has been cross-calibrated
against the I-131 standard. With its relatively long half-life (10.3 years) and similar gamma
emissions, Ba-133 is a suitable replacement for the prepared I-131 standard. At the
conclusion of the data acquisition, two 1-ml aliquots of whole blood, and the "standard" are
counted. Using this information, it is possible to calculate the % of administered
dosage/liter of whole blood at each of the timed samples. A zero time point is calculated by
dividing the total dosage by the patient's total blood volume. However, a patient-specific
blood volume is not determined, but is assumed to equal 20% of the body weight.

iii. Whole blood dosimetry

The Maximum Treatment Activity (MTA) is then calculated as the activity of I-131, which would
deliver a combined beta and gamma dose to the blood component of 200 cGy (200 rads).

This calculation will be performed using the whole body and blood clearance data from both
the I-131 and the I-124 biokinetic clearance data. The I-124 data will first be corrected for
the difference in half-lives of these two radionuclides so as to generate the "equivalent"
I-131 values.

iv. Lesion Kinetics

For those patients in which focal lesion(s) can be visualized the clearance curves and
half-lives will be determined from the images for both the I-131 and the I-124 studies. A
manually drawn region-of interest (ROI) will be placed around each lesion as visualized on
the diagnostic whole body scan performed at 48hrs post administration of the radioiodine.
This ROI will then be positioned over the comparable area on each of the scans. A background
ROI adjacent to the lesion will also be drawn. The total counts in the lesion after
background correction will be determined for each time point. In the case of the PET scans
first each PET study will be co-registered to the diagnostic scan using the Hermes image
registration tool. The coronal slices will then be added to generate a whole body scan that
is "equivalent" to that of I-131. Regions of interest will be defined in the same manner as
discussed above. A least squares single exponential fit will be applied to each of the lesion
clearance curves. The half-life of the exponential will then be computed and the values
derived for I-131 compared with I-124 for each identified lesion.

Inclusion Criteria:

- 18 years or older

- Well-differentiated thyroid carcinoma

- Referred for I-131 dosimetry

- Preparation with Recombinant Human TSH (rh TSH)

Exclusion Criteria:

- < 18 years of age

- Pregnancy or breast feeding

- Inability to comply with instructions

- Simultaneous participation or participation in any other research study within the
last month

- A body weight greater than 350 lbs

- A creatinine > 1.5 mg/ml for males and 1.4 mg/ml for females

- Preparation with thyroid hormone withdrawal(THW)